4
INFORMATION FOR THE INSTALLER
The installation, all regulations, changes and maintenance referred to in this part must only be carried out by
qualified staff.
A wrong installation can cause damage to persons, animals or things which the manufacturer cannot be held
responsible for.
The safety and automatic regulation devices on the appliances can only ever be changed by the
manufacturer or by the supplier which has been authorised to do so.
INSERTING THE HOTPLATE
After having removed the various loose parts from the internal and external packing, make sure that the
hotplate in not damaged and is suitable for the specific gas usage. The gas type label is on the underside of
the hotplate base.
In case of doubt, do not use the appliance and contact skilled personnel.
Keep all the packing parts (polystyrene foam, cardboard, staples, etc.) away from children.
Consider the critical dimensions of the appliance, before making an opening in the top surface of the bench
top. (relative measurements as per Fig 1, 2 & 21).
If your counter is produced from porous materials which tend to swell if in contact with humidity, and water, to
better protect the cut-out, use proper sea-lants on the edge which would prevent any penetration of humidity
and water.
Chamfer all exposed edges of decorative laminates to prevent further chipping.
Radius corners of the cut-out and file them to ensure smooth edges and prevent corner cracking.
Rough edges and inside corners which are not rounded as well as forced fits can contribute to cracking of
counter top laminate.
Requirements
1. Overhead clearances (Minimum values)
The minimum overhead clearances shall be in accordance with the minimum values indicated in the table
n.1 and are shown and in the fig. 1- 2
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions.
However, in no case shall the clearance between the top of the highest burner of the cooking appliance and
the range hood be less than 650mm.
Any other downward facing combustible surface less than 600mm above the top of the highest burner shall
be protected for the full width and depth of the cooking surface area.
However, in no case shall this clearance to any surface be less than 450mm.
Maximum depth for the overheads cabinet is 330mm
2. Side clearances (Minimum values)
The different side clearances shall be in accordance with the minimum values indicated in the table n.1 and
are shown and in the fig. 1- 2
The cooking surface area is defined as that part of the appliance where cooking normally takes place and
does not include those parts of the appliance containing control knobs.
Table n.1
Min. Clearances mm Min. Clearances mm
L1
500
L10
860
L2
40
L11
915
L3
50
W
890
L4
457
D
520
L5
600
B1 (*)
40*
L6
330
B2 (*)
152*
L7
925
B3 (*)
40*
L8
40
B4 (*)
152*
L9
172
Comentarios a estos manuales