c) Put in position the pressure detector directly on the burner injector afterward open the relative burner
knob at maximum position keeping it pressed, then measure the outlet pressure from the burner
injector.
d) Once the pressure checking has been carried out, replace the burner cap and flame spreader in the
correct and original position and re-connect electric power to the appliance.
8. Turn on appliance control cock and light each burner. Check for a clear blue flame without yellow tipping.
If burners show any abnormalities check that they are located properly and in line with the injector nipple.
9. Sometimes the burners will not ignite immediately and seem to ‘blow’ slightly when they do ignite. This
usually due to air in the gas lines, which will clear itself within seconds.
10. If after following the instructions given, satisfactory performance cannot be obtained, contact the local
gas authority for advice and assistance.
Electrical connection
The appliance is equipped with a 4 ft. (1.2 m.) flexible metal cable with 4 wires ready for connection to a
dedicated 4 wire grounded power supply/junction box: (fig.13)
Voltage 120/208 V a.c., Frequency 60Hz. Max Current: 3600W /20,2 A
Voltage 120/240 V a.c., Frequency 60Hz. Max Current: 4500W /22,2 A
Black wire
: connect to L1 (hot)
Red wire
: connect to L2 (hot)
White wire
: connect to N (neutral)
Green wire
: connect to GND (ground)
A dedicated line and junction box should be used to connect the oven to a 25 A circuit.
Wiring diagrams Fig. 25.
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 10. For LP Gas fit assembly
described in fig. 10.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 14) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Burner Inj. size Gas Pressure Max Rate Min Rate By-pass size
1/100mm Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] [1/100mm]
Inner 80 NG 4” 2730 799 900 264 Regulated
Dual 50 LP(Propane) 11” 2900 849 900 264 29
burner Outer N°2 x 130 NG 4” 15000 4394 4500 1318 Regulated
N°2 x 83 LP(Propane) 11” 16400 4804 4500 1318 65
CAUTION: save the orifices removed from the appliance for future use